The Accesso Sampling Chamber with distribution outlets.
For use with 110/160mm EN 1401 pipe systems
Ø350mm, combined sampling and distribution chamber, is delivered to site as a one piece unit, ready to install with no assembly required. The chamber features a robust, impact resistant, rota moulded base, with the choice of 110mm and 160mm EN 1401 main pipe connections, as well as two further 110mm moulded spigots at 90°, at the base of the unit. These side outlets are for use as a Distribution Chamber. All pipe connections come with blind ends for cutting on site, as required.
Chamber with 110mm or 160mm main inlet and 7 outlet and 2 x 110mm side distribution outlets.
Supplied with square access cover to BS EN 124 -
A15 load capacity.
About Sampling Cambers
Sampling Points or Sampling Chambers should be installed in the drainage line on the outlet side of Septic Tanks and Wastewater Treatment Plants to allow necessary sampling to check the quality of the discharge from the system before it enters the watercourse.
Sampling of Septic Tanks and Wastewater Treatment Plants is a requirement of all UK Water Authorities, and is included in the 'consent to discharge' issued by the Environment Agency. Building Regulations H2 1.23 States “The inlet and outlet pipes of a Septic Tank should be provided with access for sampling and inspection” The inlet of the sampling chamber must be a minimum of 150mm up from the base of the chamber to facilitate a sampling vessel/cup and the outlet must be at the base of the chamber. The internal diameter should be a minimum of 300mm to allow access for a sampling vessel/cup.
Size | |
Overall Height | 1465mm |
Diameter | 300mm |
Inlet Invert | 1225mm |
- Stock: In Stock
- Model: ASDC300